Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 66
Filter
1.
Arq. bras. oftalmol ; 83(2): 87-91, Mar.-Apr. 2020. tab
Article in English | LILACS | ID: biblio-1088975

ABSTRACT

ABSTRACT Purpose: The present study's aim was to compare the biomechanical properties of corneal tissue in patients who underwent deep anterior lamellar keratoplasty (DALK) surgery, with successful big bubble formation and manual lamellar dissection, during failed big bubble formation. Methods: This retrospective comparative study included 60 eyes from 60 keratoconus patients who previously underwent DALK surgery. These patients were categorized as big bubble (+) or big bubble (−) based on the success or failure of big bubble formation during the surgery. The big bubble (+) group included 42 eyes, while the big bubble (−) group had 18 eyes. Moreover, the patients were regrouped as 0.25 mm and 0.50 mm to evaluate the effects of the disparity between donor and trephine punches on the biomechanical properties of the cornea. These biomechanical properties, characterized by corneal hysteresis and the corneal resistance factor, were measured using the Ocular Response Analyzer 12 months after the surgery. Results: There was no statistically significant difference between the big bubble (+) and big bubble (−) groups in the biomechanical properties of the cornea (corneal hysteresis: 10.06, 10.25; p=0.716/corneal resistance factor: 10.15, 10.07; p=0.805, respectively). In addition, pachymetry results were not statistically different between the two groups. Multivariate regression analysis revealed that corneal hysteresis and corneal resistance factor were positively associated with central corneal thickness (p<0.001/r2=0.506; p<0.001/r2=0.561, respectively). However, the study did not demonstrate a relationship between any of the punch sizes and corneal hysteresis or between the punch sizes (p=0.673) and the corneal resistance factor (p=0.643). Conclusions: The corneal hysteresis and corneal resistance factor values were similar in big bubble and manual lamellar dissection after DALK. Thus, manual lamellar dissection was not a disadvantage considering the cornea's biomechanical properties.


RESUMO Objetivo: O objetivo do estudo foi comparar pa râmetros biomecânicos corneanos de pacientes com cirurgia de ceratoplastia lamelar anterior profunda com formação bem-sucedida de bolha e dissecção lamelar manual, frente à falha de formação da grande bolha. Métodos: Este estudo comparativo retrospectivo incluiu 60 olhos de 60 pacientes com ceratocone submetidos à cirurgia de ceratoplastia lamelar anterior profunda. Os pacientes foram agrupados como grande bolha (+) e grande bolha (-) de acordo com o sucesso da formação da grande bolha durante a cirurgia. O grupo grande bolha (+) incluiu 42 olhos, enquanto o grupo grande bolha (-) tinha 18 olhos. Além disso, para a avaliação dos efeitos da disparidade entre alterações individuais nas propriedades biomecânicas da córnea, reagrupamos os pacientes em 0,25 mm e 0,50 mm. Parâmetros biomecânicos da córnea, caracterizados por histerese corneana e fator de resistência corneana foram medidos com o ORA 12 meses após a cirurgia. Resultados: Não houve diferença estatisticamente significativa entre os grupos grande bolha (+) e grande bolha (-) em relação aos parâmetros biomecânicos da córnea (histerese corneana: 10,06, 10,25, p=0,716/fator de resistência da córnea: 10,15, 10,07, p=0,805, respectivamente). Além disso, os resultados de paquimetria não diferiram estatisticamente entre os dois grupos. A análise de regressão multivariada demonstrou que a histerese da córnea e o fator de resistência corneana estavam associados positivamente com a espessura corneana central (p<0,001/r2=0,506, p<0,001/r2=0,561 respectivamente). No entanto, o estudo não revelou associação entre qualquer um dos tamanhos de punção e histerese corneana, bem como entre os tamanhos de punção e o fator de resistência corneano (p=0,673, p=0,643). Conclusões: A histerese da córnea e os valores do fator de resistência da córnea foram comparáveis com formação de grande bolha e dissecção manual lamelar na ceratoplastia lamelar anterior profunda. Assim, a dissecção manual lamelar não foi uma desvantagem, considerando os fatores biomecânicos da córnea.


Subject(s)
Humans , Male , Female , Adult , Young Adult , Corneal Transplantation/methods , Cornea/surgery , Keratoconus/surgery , Reference Values , Biomechanical Phenomena , Multivariate Analysis , Regression Analysis , Retrospective Studies , Treatment Outcome , Cornea/physiopathology , Dissection/methods , Keratoconus/physiopathology
2.
Arq. bras. oftalmol ; 83(2): 132-140, Mar.-Apr. 2020. tab, graf
Article in English | LILACS | ID: biblio-1088966

ABSTRACT

ABSTRACT Purpose: To investigate the relationships between (i) thickness of the retinal nerve fiber layer, optic nerve head topography, and visual field parameters and (ii) corneal biomechanical properties in normal controls and patients with ocular hypertension and primary open-angle glaucoma. Methods: This observational, cross-sectional study included 68 eyes with primary open-angle glaucoma, 99 eyes with ocular hypertension and 133 control eyes. Corneal biomechanical properties, optic nerve head topographic features, retinal nerve fiber layer thickness, and visual fields were assessed in all cases. Corneal biomechanical properties, retinal nerve fiber layer thicknesses, and optic nerve head topographic features were compared among the groups. The associations between structural and functional measures of glaucomatous damage and corneal biomechanical factors were also evaluated. Results: Significantly lower corneal hysteresis and corneal resistance factor values were observed in the primary open-angle glaucoma and ocular hypertension groups as compared with the control group, but there were no significant differences between the primary open-angle glaucoma and ocular hypertension groups. In the ocular hypertension group, no associations were observed between the corneal hysteresis and corneal resistance factor with values and the structural and functional parameters. In the primary open-angle glaucoma group, positive correlations were observed between the corneal hysteresis values and the global retinal nerve fiber layer thickness (p<0.01, r=0.27), mean retinal nerve fiber layer thickness (p<0.01, r=0.33), and mean deviation (p<0.01, r=0.26), and negative correlations were observed between the corneal resistance factor values, and the cup area (p<0.01, r=-0.39), cup-to-disk ratio (p=0.02, r=-0.28), linear cup-to-disk ratio (p=0.02, r=-0.28), and cup shape (p=0.03, r=-0.26). In the control group, weak correlations were detected between the corneal hysteresis and the cup area (p=0.03, r=0.19), cup-to-disk ratio (p=0.01, r=0.21), and linear cup-to-disk ratio (p=0.01, r=0.22). Conclusions: Distinct correlations were identified between the corneal hysteresis and corneal resistance factor values and the functional and structural parameters in the primary open-angle glaucoma and control groups. Corneal hysteresis and corneal resistance factor may have different roles in the pathophysiology of glaucoma.


RESUMO Objetivo: Investigar as relações entre (i) espessura da camada de fibras nervosas da retina, topografia do nervo óptico e parâmetros do campo visual e (ii) propriedades biomecânicas da córnea, em controles normais e pacientes com hiperten são ocular e glaucoma primário de ângulo aberto. Métodos: Este estudo observacional, transversal, incluiu 68 olhos com glaucoma primário de ângulo aberto, 99 olhos com hipertensão ocular e 133 olhos controle. As propriedades biomecânicas da córnea, as características topográficas da cabeça do nervo óptico, a espessura da camada de fibras nervosas da retina e os campos visuais foram avaliados em todos os casos. As propriedades biomecânicas da córnea, a espessura da camada de fibras nervosas da retina e as características topográficas da cabeça do nervo óptico foram comparadas entre os grupos. As associações entre medidas estruturais e funcionais de danos glaucomatosos e fatores biomecânicos da córnea também foram avaliadas. Resultados: Valores de histerese corneana e da resistência corneana foram significativamente menores nos grupos com glaucoma primário de ângulo aberto e hipertensão ocular em com paração ao grupo controle, mas não houve diferenças significativas entre os grupos de glaucoma primário de ângulo aberto e hipertensão ocular. No grupo com hipertensão ocular, não foram observadas associações entre histerese da córnea e o fator de resistência corneana com os valores e os parâmetros estruturais e funcionais. No grupo com glaucoma primário de ângulo aberto foram observadas correlações positivas entre os valores de histerese corneana e a espessura a camada de fibras nervosas da retina (p<0,01, r=0,27), espessura média da camada de fibras nervosas da retina (p<0,01, r=0,33) e desvio médio (p<0,01, r=0,26), e correlações negativas entre o os valores do fator de resistência da córnea e a área de escavação (p<0,01, r=-0,39), a relação escavação/disco (p=0,02, r=-0,28), a relação copo-para-disco linear (p=0,02, r=-0,28) e a forma da escavação (p=0,03, r=-0,26). No grupo controle, correlações foram detectadas entre a histerese da córnea e área de escavação (p=0,03, r=0,19), relação escavação/disco (p=0,01, r=0,21) e relação copo-para-disco linear (p=0,01, r=0,22). Conclusões: Correlações distintas foram identificadas entre histerese da córnea e os valores de resistência da córnea e os parâmetros funcionais e estruturais nos grupos de glaucoma primário de ângulo aberto e controle. A histerese da córnea e o fator de resistência da córnea podem ter diferentes papéis na fisiopatologia do glaucoma.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Retina/pathology , Glaucoma, Open-Angle/pathology , Ocular Hypertension/pathology , Cornea/pathology , Nerve Fibers/pathology , Reference Values , Retina/physiopathology , Biomechanical Phenomena , Visual Fields/physiology , Case-Control Studies , Linear Models , Glaucoma, Open-Angle/physiopathology , Ocular Hypertension/physiopathology , Cross-Sectional Studies , Cornea/physiopathology , Intraocular Pressure
3.
Arq. bras. oftalmol ; 82(5): 377-380, Sept.-Oct. 2019. tab, graf
Article in English | LILACS | ID: biblio-1019430

ABSTRACT

ABSTRACT Purpose: To assess the frequency of corneal astigmatism before cataract surgery in a Brazilian sample. Methods: This clinic-based cross-sectional study was conducted at the Bonsucesso Federal Hospital, Rio de Janeiro, Brazil. Charts of patients who underwent cataract surgery over a two-year period were retrospectively reviewed, and preoperative keratometric measurements were collected and analyzed. Results: A total of 1707 eyes of 1045 patients were enrolled. The corneal astigmatism was less than 1.0 D in 971 eyes (56.9%), 1.0-1.99 D in 496 eyes (29.1%), 2.0-2.99 D in 157 eyes (9.2%), and more than 3.0 D in 83 eyes (4.9%). The mean corneal astigmatism was 0.92 ± (SD) 0.96 D (range 0 - 10.25 D). Conclusion: Over 40% of the patients undergoing cataract surgery enrolled in this study had more than 1.0 D of corneal astigmatism and may benefit from the use of toric intraocular lenses. These data can be useful for planning to make this technology available for patients.


RESUMO Objetivo: Avaliar a prevalência do astigmatismo corneano antes da cirurgia de catarata em pacientes brasileiros. Métodos: Este estudo transversal de base clínica foi realizado no Hospital Federal de Bonsucesso, Rio de Janeiro, Brasil. Os prontuários de pacientes submetidos à cirurgia de catarata durante um período de dois anos foram revisados retrospectivamente, e as medidas ceratométricas pré-operatórias foram coletadas e analisadas. Resultados: Um total de 1.707 olhos de 1045 pacientes foram incluídos. O astigmatismo corneano foi menor que 1,0 D em 971 olhos (56,9%), 1,0-1,99 D em 496 olhos (29,1%), 2,0-2,99 D em 157 olhos (9,2%) e mais de 3,0 D em 83 olhos (4,9%). A média do astigmatismo corneano foi de 0,92 ± (SD) 0,96 D (intervalo 0-10,25 D). Conclusão: Mais de 40% dos pacientes estudados submetidos à cirurgia de catarata incluídos neste estudo tinham mais de 1,0 D de astigmatismo corneano e podem se beneficiar do uso de lentes intraoculares tóricas. Esses dados podem ser úteis no planejar a disponibilização dessa tecnologia para os pacientes.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Astigmatism/epidemiology , Cataract/complications , Cataract Extraction , Corneal Diseases/epidemiology , Brazil/epidemiology , Prevalence , Cross-Sectional Studies , Retrospective Studies , Cornea/physiopathology , Hospitals, Public
4.
Arq. bras. oftalmol ; 82(1): 45-50, Jan.-Feb. 2019. tab
Article in English | LILACS | ID: biblio-973877

ABSTRACT

ABSTRACT Purpose: The aim of the present study was to compare the severity of ocular and systemic findings among patients with primary Sjögren syndrome. Methods: The study followed a prospective controlled design and comprised two groups; the test group included 58 eyes of 58 patients newly diagnosed with primary Sjögren syndrome with poor dry eye test findings and the control group included 45 right eyes of 45 healthy age- and sex-matched individuals. The ocular surface disease index score, tear osmolarity, Schirmer I test without anesthesia, fluorescein tear breakup time, and cornea-conjunctiva staining with lissamine green (van Bijsterveld scoring) were used to examine tear function in the patients via a complete ophthalmological examination. The results were graded and classified on the basis of a Dry Eye WorkShop report and results of the corneal and conjunctival staining test, Schirmer's test, and fluorescein tear breakup time test. Discomfort, severity and frequency of symptoms, visual symptoms, conjunctival injection, eyelid-meibomian gland findings, and corneal-tear signs were interpreted. Disease activity was scored per the EULAR Sjögren's syndrome disease activity index (ESSDAI) via systemic examination and laboratory evaluations, and the EULAR Sjögren's syndrome patient-reported index (ESSPRI) assessed via a survey of patient responses. Results: Mean patient age was 48.15 ± 16.34 years in the primary Sjögren syndrome group and 44.06 ± 9.15 years in the control group. Mean fluorescein tear breakup time was 4.51 ± 2.89s in the primary Sjögren syndrome group and 10.20 ± 2.39 s in the control group. Mean Schirmer I test result was 3.51 ± 3.18 mm/5 min in the primary Sjögren syndrome group and 9.77±2.30 mm/5 min in the control group. Mean ocular surface disease index score was 18.56 ± 16.09 in the primary Sjögren syndrome group, and 19.92 ± 7.16 in the control group. Mean osmolarity was 306.48 ± 19.35 in the primary Sjögren syndrome group, and 292.54 ± 10.67 in the control group. Mean lissamine green staining score was 2.17 ± 2.76 in the primary Sjögren syndrome group, and 0.00 in the control group. Statistically significant differences were found berween the primary Sjögren syndrome group and control group in terms of fluorescein tear breakup time, Schirmer's test, lissamine green staining, and osmolarity tests (p=0.036, p=0.041, p=0.001, and p=0.001 respectively). The Dry Eye WorkShop score was 2.15 ± 0.98, the EULAR Sjögren's syndrome disease activity index score was 11.18 ± 4.05, and the EULAR Sjögren's syndrome patient-reported index score was 5.20±2.63. When potential associations of the Dry Eye Workshop Study scores and osmolarity scores with the Eular Sjögren's syndrome disease activity index scores were evaluated, the results were found to be statistically significant (p=0.001, p=0.001 respectively). Conclusion: The results showed an association between dry eye severity and systemic activity index in primary Sjögren syndrome patients.


RESUMO Objetivo: O objetivo do presente estudo foi comparar a gravidade dos achados oculares e sistêmicos entre pacientes com síndrome de Sjögren primária. Métodos: O estudo seguiu um delineamento prospectivo controlado e compreendeu dois grupos; o grupo de teste incluiu 58 olhos de 58 pacientes recém-diagnosticados com síndrome de Sjögren primária com resultados deficientes no teste de olho seco e o grupo controle incluiu 45 olhos direitos de 45 indivíduos saudáveis pareados idade e sexo. A contagem do índice de doença da superfície ocular, osmolaridade lacrimal, teste de Schirmer I sem anestesia, tempo de ruptura da fluoresceína e coloração córnea-conjuntiva com verde de lissamina (índice de van Bijsterveld) foram utilizados para examinar a função lacrimal dos pacientes através de exame oftalmológico completo. Os resultados foram classificados com base em um relatório da "Dry Eye Workshop" e resultados do teste de coloração da córnea e conjuntiva, teste de Schirmer e teste do tempo de ruptura da fluoresceína. Desconforto, gravidade e frequência dos sintomas, sintomas visuais, injeção conjuntival, achados das glândulas palpebrais e sinais da córnea foram interpretados. A atividade da doença foi avaliada pelo índice de atividade da doença da síndrome de Sjögren EULAR por meio de exame sistêmico e avaliações laboratoriais, e o índice relatado pelo paciente da síndrome de Sjörgen EULAR avaliado através de uma pesquisa das respostas dos pacientes. Resultados: A média de idade dos pacientes foi de 48,15 ± 16,34 anos no grupo da Síndrome de Sjörgen primária e 44,06 ± 9,15 anos no grupo controle. O tempo médio de ruptura da fluoresceína foi de 4,51 ± 2,89 s no grupo síndrome de Sjögren primária e 10,20 ± 2,39 s no grupo controle. O resultado do teste de Schirmer I médio foi de 3,51 ± 3,18 mm/5 min no grupo síndrome de Sjögren primária e de 9,77 ± 2,30 mm/5 min no grupo controle. O índice médio de doença da superfície ocular foi de 18,56 ± 16,09 no grupo síndrome de Sjögren primária e 19,92 ± 7,16 no grupo controle. A osmolaridade média foi 306,48 ± 19,35 no grupo síndrome de Sjögren primária e 292,54 ± 10,67 no grupo controle. O resultado médio de coloração com lissamina verde foi de 2,17 ± 2,76 no grupo síndrome de Sjögren primária e 0,00 no grupo controle. Diferenças es­tatisticamente significativas foram encontradas entre o com sín­­drome de Sjögren primária e o grupo controle em termos de tempo de ruptura da fluoresceína lacrimal, teste de Schirmer I, coloração com lissamina verde e osmolaridade (p=0,036, p=0,041, p=0,001, p=0,001 respectivamente). O índice Estudo do Olho Seco foi de 2,15 ± 0,98, o índice de atividade da doença da síndrome de Sjögren EULAR foi de 11,18 ± 4,05 e a pontuação do índice relatado pelo paciente EULAR Sjögren foi de 5,20 ± 2,63. Quando associações potenciais do Estudo do Olho Seco e o índice da osmolaridade foram comparados a pontuação de índice de atividade da doença da síndrome de Sjögren EULAR, os resultados foram estatisticamente significantes (p=0,001, p=0,001 respectivamente). Conclusão: Os resultados mostraram uma associação entre a gravidade do olho seco e o índice de atividade sistêmica em pacientes com síndrome de Sjögren primária.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Dry Eye Syndromes/physiopathology , Sjogren's Syndrome/physiopathology , Osmolar Concentration , Reference Values , Staining and Labeling , Tears/physiology , Severity of Illness Index , Dry Eye Syndromes/pathology , Sjogren's Syndrome/pathology , Case-Control Studies , Prospective Studies , Surveys and Questionnaires , Conjunctiva/physiopathology , Conjunctiva/pathology , Cornea/physiopathology , Cornea/pathology
5.
Arq. bras. oftalmol ; 80(5): 290-295, Sept.-Oct. 2017. tab, graf
Article in English | LILACS | ID: biblio-888144

ABSTRACT

ABSTRACT Purpose: To evaluate the changes in several ocular parameters, including choroidal thickness, during and after hemodialysis. Methods: Twenty-seven eyes of 27 patients with chronic renal failure undergoing hemodialysis were included. The patients underwent an ophthalmic examination, including intraocular pressure, central corneal thickness, iridocorneal angle, subfoveal choroidal thickness, and blood pressure, just before a hemodialysis session, during the second hour of the session, and half an hour after the end of the session. Body weight was measured before and after the session, and ultrafiltration volume was noted after the session. Central corneal thickness, intraocular pressure, and subfoveal choroidal thickness were measured by optical coherence tomography. Results: In comparison with baseline levels, mean intraocular pressure and central corneal thickness increased significantly during the second hour of hemodialysis (p=0.001 and p=0.011, respectively) and showed no significant changes after hemodialysis (p=0.844 and p=0.246, respectively). Mean iridocorneal angle did not significantly change during the second hour of hemodialysis (p=0.101) and after hemodialysis (p=0.589). Mean subfoveal choroidal thickness was significantly lower during the second hour of hemodialysis (p<0.001) and after hemodialysis (p<0.001). Conclusions: Mean intraocular pressure and central corneal thickness increased and subfoveal choroidal thickness decreased during the second half of the hemodialysis session. During the second half of the session, intraocular pressure and central corneal thickness had a trend toward reduction, while subfoveal choroidal thickness had a relatively steady course. Because of possible fluctuations in the values, it would be reasonable to evaluate the changes not only from before to after hemodialysis but also during hemodialysis when analyzing the ocular effects of dialysis.


RESUMO Objetivo: Avaliar as alterações em vários parâmetros oculares, incluindo a espessura da coroide, durante e após a hemodiálise. Métodos: Foram incluídos 27 olhos de 27 pacientes portadores de insuficiência renal crônica e submetidos a hemodiálise. Todos foram submetidos ao exame oftalmológico, incluindo pressão intraocular, medida da espessura corneana central, ângulo iridocorneal e espessura da coroide subfoveal, além da medida da pressão arterial. A espessura corneana central, o ângulo iridocorneal e a espessura da coroide subfoveal foram medidos através da tomografia de coerência óptica. Os exames foram realizados logo antes, durante (na segunda hora) e meia hora após uma única sessão de hemodiálise. O peso corporal foi medido antes e depois da sessão, e os volumes de ultra filtração foram anotados após a sessão de hemodiálise. Resultados: Em comparação com os níveis basais, a pressão intraocular média e a espessura corneana central aumentaram significativamente na segunda hora de hemodiálise (p=0,001 e p=0,011, respectivamente), mas não houve diferença após a hemodiálise (p=0,844 para pressão intraocular e p=0,246 para espessura corneana central). O ângulo iridocorneal mostrou ligeira diminuição na segunda hora de hemodiálise (p=0,101) e após a sessão de hemodiálise (p=0,589), porém esta redução não foi estatisticamente significativa. Já a espessura da coroide subfoveal mostrou uma redução significativa tanto na segunda hora de hemodiálise (p<0,001) quanto após a sessão de hemodiálise (p<0,001). Conclusões: A pressão intraocular e a espessura corneana central aumentaram, enquanto a espessura da coroide subfoveal diminuiu na primeira metade da sessão de hemodiálise. Na segunda metade da sessão, a pressão intraocular e a espessura corneana central mostraram uma tendência de redução, enquanto a espessura da coroide subfoveal permaneceu estável. Ao analisar os efeitos oculares da hemodiálise, seria interessante avaliar as mudanças não só antes e depois da sessão, como também durante a hemodiálise, devido a possíveis flutuações dos valores.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Choroid/anatomy & histology , Renal Dialysis/adverse effects , Cornea/anatomy & histology , Intraocular Pressure/physiology , Kidney Failure, Chronic/therapy , Retina/anatomy & histology , Retina/physiopathology , Time Factors , Blood Pressure/physiology , Body Weight , Choroid/physiopathology , Choroid/diagnostic imaging , Statistics, Nonparametric , Cornea/physiopathology , Cornea/diagnostic imaging , Tomography, Optical Coherence/methods , Corneal Pachymetry/methods
6.
Arq. bras. oftalmol ; 80(5): 309-312, Sept.-Oct. 2017. tab
Article in English | LILACS | ID: biblio-888139

ABSTRACT

ABSTRACT Purpose: To evaluate the corneal biomechanical features and central corneal thickness in ankylosing spondylitis patients and to evaluate correlations of these parameters with disease activity. Methods: The study included 51 patients diagnosed with ankylosing spondylitis (mean age, 40.80 ± 13.15 years; range, 18-72 years) and 34 age- and sex-matched healthy controls (mean age, 42.00 ± 12.32 years; range, 18-60 years). All underwent a complete ophthalmological and physical examination, including visual acuity testing and biomicroscopic anterior and posterior segment examinations. Corneal hysteresis, corneal resistance factor, Goldmann-correlated intraocular pressure, and corneal compensated intraocular pressure were evaluated with an ocular response analyzer, and the central corneal thickness was measured with Sirius® corneal tomography. The Bath Ankylosing Spondylitis Disease Activity Index, Functional Index, and Metrology Index scores were recorded. Results: In the ankylosing spondylitis patients, the mean disease duration was 7.73 ± 6.05 (range, 1-30) years. There was no statistically significant difference between the patients and controls in the corneal biomechanical features. The Goldmann-correlated intraocular pressure and corneal compensated intraocular pressure both showed positive correlations with age (p=0.003 and p=0.001, res­pectively). There was a negative correlation between corneal hysteresis and disease duration (p=0.002), and between central corneal thickness and the Bath Ankylosing Spondylitis Metrology Index score (p=0.003). Conclusion: This study demonstrated a significant negative correlation between corneal hysteresis and disease duration in ankylosing spondylitis patients. Furthermore, the central corneal thickness value decreased with an increase in Bath Ankylosing Spondylitis Metrology Index score, which may result in an underestimate of intraocular pressure readings and thus an inaccurate risk assessment of glaucoma.


RESUMO Objetivo: Avaliar as características biomecânicas da córnea e espessura central da córnea em pacientes com espondilite anquilosante e analisar a correlação destes parâmetros no grupo de estudo com a atividade da doença. Métodos: Foram incluídos no estudo 51 pacientes com diagnóstico de espondilite anquilosante e 34 controles saudáveis com idade e sexo. Todos os sujeitos foram submetidos a um exame oftalmológico e físico completo, incluindo exames de acuidade visual, exames de segmento anterior e posterior biomicroscópicos. Foram avaliados o coeficiente de resistência da córnea, a pressão intraocular correlacionada com Goldmann e a pressão intraocular compensada da córnea com o analisador de resposta ocular, a espessura corneana central com a tomografia corneana pelo Sirius®. Se o índice de atividade da doença de espondilite anquilosante de banho, o índice funcional de espondilite anquilosante de banho, o índice de metrologia de espondilite anquilosante de banho. Resultados: Foram incluídos no estudo 51 pacientes com idade média de 40,80 ± 13,15 (intervalo: 18-72) anos e 34 casos de controle com idade média de 42,00 ± 12,32 (intervalo: 18-60) anos. No grupo espondilite anquilosante a duração média da doença foi de 7,73 ± 6,05 (1,00-30,00) anos. Não houve diferença estatisticamente significante entre dois grupos quanto às características biomecânicas da córnea. Na análise de correlação, no grupo de estudo; pressão intraocular correlacionada com Goldmann e pressão intraocular compensada da córnea estavam positivamente correlacionados com a idade (p=0,003, p=0,001, respectivamente). Houve uma correlação negativa entre a duração da doença e CH (p=0,002), e entre índice de metrologia de espondilite anquilosante de banho e espessura corneana central (p=0,003). Conclusão: Este estudo demonstrou correlação negativa significativa entre a duração da doença e a histerese corneal em pacientes com espondilite anquilosante. Além disso, com um aumento na pontuação de índice de metrologia de espondilite anquilosante de banho, o valor de espessura corneana central também estava di­minuindo o que pode causar uma diminuição nas leituras de pressão intraocular artificialmente e resultar em avaliação de risco imprecisa de glaucoma.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Young Adult , Spondylitis, Ankylosing/pathology , Cornea/pathology , Corneal Diseases/pathology , Spondylitis, Ankylosing/complications , Biomechanical Phenomena , Severity of Illness Index , Case-Control Studies , Cell Count , Glaucoma/etiology , Glaucoma/physiopathology , Risk Factors , Cornea/physiopathology , Corneal Diseases/complications , Corneal Diseases/physiopathology , Corneal Topography , Corneal Pachymetry , Intraocular Pressure
7.
Rev. cuba. oftalmol ; 30(3): 1-11, jul.-set. 2017. ilus
Article in Spanish | LILACS | ID: biblio-901385

ABSTRACT

Este trabajo tiene como objetivo conocer los avances más novedosos relacionados con el estudio de las características biomecánicas de la córnea y su posible relación en el diagnóstico del glaucoma. Se realizó una búsqueda en la plataforma Infomed, específicamente en la Biblioteca Virtual de Salud, con el objetivo de conocer los avances más novedosos relacionados con el estudio de las características biomecánicas de la córnea y su posible relación en el diagnóstico del glaucoma. La biomecánica corneal es la facultad de resistencia y flexión simultánea de las moléculas de colágeno en las diferentes capas de la córnea. Trata del equilibrio y de la deformación del tejido corneal sometido a cualquier acción exterior. La histéresis corneal, junto con el factor de resistencia corneal, son medidas que pueden ser proporcionadas por el analizador de respuesta ocular. La existencia de un bajo valor de estas dos medidas pudiera considerarse como un factor de riesgo de progresión en el glaucoma(AU)


The purpose of this work is to know the more novel advances related with the study of the biomechanic characteristic of the cornea and its possible relationship in the diagnosis of the glaucoma. A search was made in Infomed platform, particularly in the Virtual Library of Health, to find out the most advanced in the study of the corneal biomechanical properties and its possible relation with the diagnose of glaucoma. Corneal biomechanical is the power of the resistance and flexion simultaneity of collagen molecules of the different corneal layer. It is the balance and deformity of the corneal tissue submitted to an external action. Corneal hysteresis and corneal resistance factor are two corneal biomechanical properties measured by the Ocular Response Analyzer. The existence of a low value of these two properties may be considered as progression factors in glaucoma(AU)


Subject(s)
Humans , Cornea/physiopathology , Glaucoma/diagnosis , Review Literature as Topic , Technological Development/adverse effects
8.
Arq. bras. oftalmol ; 80(3): 148-153, May-June 2017. tab, graf
Article in English | LILACS | ID: biblio-888112

ABSTRACT

ABSTRACT Purpose: To compare central corneal backscatter obtained from Scheimpflug images between patients with insulin-dependent and non-insulin-dependent diabetes mellitus (IDDM and NIDDM, respectively) and healthy controls. Methods: Seven patients with IDDM (7 eyes), eleven patients with NIDDM (11 eyes), and sixteen healthy subjects (16 eyes) were included in this pilot study. Scheimpflug imaging system (Pentacam, Oculus Inc., Germany) was used to obtain optical sections of the cornea. Seven meridians were analyzed for each eye, oriented from 70° to 110°. Optical density values for the central 3-mm and 5-mm zones of the cornea were obtained by image analysis using external software. Results: Corneal backscatter was significantly higher in the diabetic patients than in the controls for the central 3-mm (p=0.016) and 5-mm (p=0.014) zones. No significant differences in corneal backscatter were found between the IDDM and NIDDM groups for either zone (both p>0.05). In the NIDDM group, significant correlations were observed for both central zones between corneal backscatter and age (3 mm: r=0.604, p=0.025; 5 mm: r=0.614, p=0.022) and central corneal thickness (3 mm: r=0.641, p=0.017; 5 mm: r=0.671, p=0.012); this was not found in the IDDM group (p>0.05). The presence of diabetes showed a significant effect on central corneal backscatter (Kruskal-Wallis test, p<0.001). Conclusions: Diabetic patients showed higher values of corneal light backscatter than healthy subjects. Corneal optical density analysis may be a useful tool for monitoring and assessing the ocular changes caused by diabetes.


RESUMO Objetivo: Determinar os valores de retroespalhamento luminoso central da córnea em pacientes diabéticos dependentes (IDDM) e não dependentes (NIDDM) de insulina, comparados com controles saudáveis, a partir de imagens de Scheimpflug. Métodos: Foram incluídos neste estudo piloto sete pacientes com IDDM (7 olhos), onze pacientes com NIDDM (11 olhos) e dezesseis indivíduos saudáveis (16 olhos). O sistema de Scheimpflug (Pentacam, Oculus Inc. Germany) foi utilizado para obter secções ópticas da córnea. Foram analisados sete meridianos para cada olho, orientados de 70º a 110º. A análise de imagem por meio de software externo permitiu a obtenção de valores da densidade óptica para os 3 e 5 mm centrais da córnea. Resultados: O retroespalhamento luminoso corneano foi significativamente maior em pacientes diabéticos para os 3 mm centrais (p=0,016) e para os 5 mm centrais (p=0,014) em relação ao grupo controle. Não foram encontradas diferenças significativas entre os grupos IDDM e NIDDM para cada zona analisada (p>0,05 em ambos os casos). No grupo NIDDM, observaram-se correlações significativas para as zonas centrais de 3 mm e 5 mm, entre retroespalhamento luminoso corneano e idade (r=0,604 p=0,025 e r=0,614 p=0,022, respectivamente) e espessura central corneana (r=0,641 p=0,017; r=0,671 p=0,012, respectivamente), o que não foi encontrado no grupo IDDM (p>0,05). O teste de Kruskall-Wallis indicou que a presença de diabete tem um efeito significativo sobre a retroespalhamento central da córnea (p<0,001). Conclusões: Pacientes diabéticos apresentaram valores mais elevados de retroespalhamento luminoso corneano do que indivíduos saudáveis. A análise da densidade óptica corneana pode ser uma ferramenta útil para monitorar e avaliar as alterações oculares causadas pela diabete.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Corneal Diseases/physiopathology , Corneal Diseases/diagnostic imaging , Diabetes Mellitus, Type 1/physiopathology , Diabetes Mellitus, Type 2/physiopathology , Reference Values , Visual Acuity/physiology , Case-Control Studies , Pilot Projects , Reproducibility of Results , Age Factors , Statistics, Nonparametric , Cornea/physiopathology , Corneal Diseases/etiology , Diabetes Mellitus, Type 1/complications , Diabetes Mellitus, Type 2/complications , Diagnostic Techniques, Ophthalmological , Corneal Pachymetry , Anterior Eye Segment/physiopathology
9.
Arq. bras. oftalmol ; 80(3): 202-206, May-June 2017. tab, graf
Article in English | LILACS | ID: biblio-888109

ABSTRACT

ABSTRACT Purpose: Studies have suggested that corneal biomechanical properties influence intraocular pressure (IOP) measurements, namely central corneal thickness (CCT) and corneal hysteresis (CH). The present study aimed to investigate the associations of CH and CCT with glaucoma development. Methods: We performed a review of the literature and meta-analysis of observational studies (2006-2016) that included both adult glaucoma patients and controls and reported CCT and CH as outcomes. Nineteen studies were conside red eligible, and the mean difference (MD) between groups (patient and control) for both variables was used for statistical analyses. Results: A total of 1,213 glaucoma and 1,055 healthy eyes were studied. Quan titative analysis suggested that CH was significantly lower in the glaucoma group than in the control group (MD=-1.54 mmHg, 95% CI [-1.68, -1.41], P<0.0001). Additionally, CCT was significantly lower in the glaucoma group than in the control group (MD=-8.49 µm, 95% CI [-11.36, -5.62], P<0.001). Conclusion: Corneal properties appear to differ between glaucoma patients and healthy controls. Our results emphasize the importance of corneal biomechanical properties in IOP interpretation and should support further studies on the influence of CH and CCT in glaucoma screening and diagnosis.


RESUMO Objetivo: A literatura sugere que as propriedades biomecânicas da córnea, nomeadamente a espessura central da córnea (ECC) e a histerese corneana (HC), influenciam a medição da pressão intraocular (PIO). Este estudo teve como objetivo investigar a associação entre a ECC e a HC e o desenvolvimento de glaucoma. Métodos: Revisão da literatura e meta-análise. Foram incluídos estudos observacionais, publicados entre 2006 e 2016, que integrassem um grupo controle e um grupo de pacientes com glaucoma em que estes dois grupos apresentassem, igualmente, a ECC e a HC como parâmetros. Dezenove estudos foram considerados elegíveis e a diferença média (MD) daqueles parâmetros nos dois grupos foi utilizada para análise estatística. Resultados: Estudaram-se um total de 1.213 olhos com glaucoma e 1.055 olhos saudáveis. A análise quantitativa revelou que a HC é significativamente mais baixa no grupo de doentes com glaucoma quando comparada com o grupo controle (MD=-1,54 mmHg, intervalo de confiança de 95% [-1,68-1,41], P<0,00001). A ECC foi, também, significativamente mais baixa no grupo glaucoma quando comparada com os indivíduos saudáveis MD=-8,49 µm, intervalo de confiança de 95% [-11,36, -5,62], P<0,001). Conclusão: Os pacientes com glaucoma parecem possuir propriedades corneanas diferentes das que apresentam os indivíduos saudáveis. Os resultados enfatizam a importância das propriedades biomecânicas da córnea na interpretação da PIO e devem contribuir para novos estudos sobre a influência da HC e da ECC no rastreio e diagnóstico do glaucoma.


Subject(s)
Humans , Glaucoma/physiopathology , Cornea/physiopathology , Corneal Pachymetry , Intraocular Pressure/physiology , Reference Values , Biomechanical Phenomena/physiology , Case-Control Studies , Glaucoma/pathology , Risk Factors , Cornea/pathology , Observational Studies as Topic
10.
Arq. bras. oftalmol ; 79(5): 285-288, Sept.-Oct. 2016. tab, graf
Article in English | LILACS | ID: biblio-827973

ABSTRACT

ABSTRACT Purpose: To evaluate the central corneal thickness (CCT), corneal volume (CV), and anterior and posterior corneal surfaces using the Scheimpflug imaging system in patients diagnosed with tilted disc syndrome (TDS). Methods: The study group (Group 1) and the control group (Group 2) comprised 35 eyes of 35 age-, sex-, and refraction-matched cases. All cases underwent a full ophthalmic examination that included cycloplegic refraction, axial ocular length measurement, and Scheimpflug imaging. Results: The mean age was 34.68 ± 15.48 years in Group 1 and 34.11 ± 12.01 years in Group 2 (p=0.864). The gender distribution was 18 males and 17 females in Group 1 and 16 males and 19 females in Group 2 (p=0.618). All subjects were Caucasian. The spherical equivalent was 3.62 ± 1.75 D in Group 1 and 3.69 ± 1.51 D in Group 2 (p=0.850). There was no significant difference in age, sex, race, or spherical equivalent between groups. There was no significant difference in mean keratometric value and CV3 (the CV in the central 3 mm) between groups (p=0.232 and 0.172, respectively). There were statistically significant differences in CCT, CV5, and CV7 (CV in the central 5 and 7 mm3, respectively) and total CV between groups (p=0.008, 0.003, 0.023, and 0.019, respectively). The values of all parameters were lower in the study group than in the control group. There was also a statistically significant difference in the anterior elevation parameters of the cornea between groups (p<0.05). The mean values of Group 1 were higher than those of Group 2. There were statistically significant differences in the two parameters referring to the posterior elevation of the cornea between the two groups (p<0.05). Conclusion: The results of this study showed that eyes with TDS have thinner CCT, lower CV, and different anterior corneal curvature than normal eyes.


RESUMO Objetivo: Avaliar a espessura central da córnea (CCT), o volume de córnea (CV), e a superfície corneana anterior e posterior utilizando sistema de imagem Scheimpflug em pacientes com diagnóstico de síndrome do disco inclinado (TDS). Métodos: O grupo de estudo (grupo 1) e o grupo controle (grupo 2) consistiu de 35 olhos de 35 pacientes pareados por idade, sexo e refração em cada grupo. Todos os casos foram submetidos a um exame oftalmológico completo incluindo refração sob cicloplegia, medida do comprimento axial ocular e avaliação por Scheimpflug. Resultados: A idade média foi de 34,68 ± 15,48 anos no grupo 1 e 34.11 ± 12,01 anos no grupo 2 (p=0,864). A distribuição por sexo foi de 18 homens e 17 mulheres do grupo 1 e 16 homens e 19 mulheres no grupo 2 (p=0,618). Todos os indivíduos eram caucasianos. O equivalente esférico foi 3,62 ± 1,75 D no Grupo 1 e 3,69 ± 1,51 D no Grupo 2 (p=0,850). Não houve diferença significativa entre os dois grupos para idade, sexo, raça e equivalente esférico. Não houve diferença significativa entre os dois grupos para o valor médio ceratométrico e CV3 (o volume da córnea na central 3 mm) (p=0,232, p=0,172, respectivamente). Houve diferença estatisticamente significativa entre os dois grupos para CCT, CV5, CV7 (volume de córnea na região central 5 e 7 mm, respectivamente) e CV total (p=0,008, p=0,003, p=0,023 e p=0,019, respectivamente). Os valores do grupo de estudo foram menores do que o grupo controle para todos os parâmetros. Houve também diferença estatisticamente significativa entre os dois grupos nos parâmetros elevação anterior da córnea (p<0,05). Os valores médios do grupo 1 foram maiores do que o grupo 2. Não houve diferença entre os dois grupos para os dois parâmetros referentes à elevação posterior da córnea (p<0,05). Conclusões: Nosso estudo mostrou que os olhos com TDS apresentam CCT mais fina, menor volume da córnea e alterações na curvatura corneana anterior quando comparados aos olhos normais.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Young Adult , Optic Disk/abnormalities , Optic Disk/pathology , Optic Nerve Diseases/physiopathology , Cornea/pathology , Optic Disk/physiopathology , Organ Size , Reference Values , Syndrome , Visual Acuity , Case-Control Studies , Cross-Sectional Studies , Statistics, Nonparametric , Cornea/physiopathology , Cornea/diagnostic imaging , Corneal Topography/methods , Corneal Pachymetry/methods , Intraocular Pressure
12.
Arq. bras. oftalmol ; 78(6): 363-366, Nov.-Dec. 2015. tab, graf
Article in English | LILACS | ID: lil-768169

ABSTRACT

ABSTRACT Purpose: To quantitatively analyze corneal esthesia in patients undergoing photorefractive keratectomy (PRK) surgery. Methods: Forty-five patients selected for PRK in one eye underwent corneal esthesia using a Cochet-Bonnet esthesiometer preoperatively and 30 and 90 days postoperatively. Patients with a refractive diopter error of 4 or greater received intraoperative 0.02% mitomycin C for 20 s. Results: Twenty-four (53.3%) of the 45 eyes received intraoperative 0.02% mitomycin. Decreased sensitivity was observed on postoperative day 30. By postoperative day 90, corneal esthesia had normalized but remained 14.9% lower than preoperative levels. In the mitomycin group, no recovery of corneal esthesia to normal sensitivity levels was observed. The mean esthesiometer level was 39.2 mm on postoperative day 90 (P<0.001). Conclusions: The results of the present study demonstrate recovery of corneal esthesia to normal levels at 90 days postoperatively in patients who did not receive mitomycin C. In patients administered mitomycin C, a 23.59% reduction in the corneal touch threshold was observed compared with preoperative levels indicating a failure of recovery to normal levels.


RESUMO Objetivo: Análise quantitativa da estesia corneal em pacientes submetidos à cirurgia refrativa (PRK). Métodos: Estudo prospectivo, longitudinal e intervencionista, analisando 45 olhos com estesiômetro de Cochet Bonnet no período pré-operatório, no 30º dia após a cirurgia e no 90º dia após cirurgia refrativa. Os pacientes com erro refracional maior ou igual a 4 dioptrias, foram submetidos ao uso de mitomicina 0,02%, por período de 20 segundos no intraoperatório. Resultados: Observou-se diminuição da sensibilidade corneal no 30º dia em todos os olhos, retornando a níveis próximo ao normal no 90º dia, apresentando redução média final de 14,9%. Mitomicina C foi utilizada em 24 (53,3%) dos 45 olhos examinados. No grupo que recebeu mitomicina C, não houve recuperação da estesia normal (média de 39,2 mm) (p<0,001), após 90 dias de cirurgia. Conclusão: Com base nos resultados obtidos, verificamos que ocorreu recuperação da estesia corneal próximo ao normal 90 dias após a cirurgia, porém inferior aos valores iniciais, no grupo sem o uso de mitomicina C intraoperatória. No entanto, no grupo submetido ao uso de mitomicina, não houve a recuperação da sensibilidade corneal a níveis normais, mesmo após o período de 90 dias.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Young Adult , Cornea/physiopathology , Cornea/surgery , Lasers, Excimer/therapeutic use , Photorefractive Keratectomy/methods , Intraoperative Period , Lasers, Excimer/adverse effects , Mitomycin/therapeutic use , Nucleic Acid Synthesis Inhibitors/therapeutic use , Postoperative Period , Prospective Studies , Photorefractive Keratectomy/adverse effects , Reference Values , Sensation Disorders/etiology , Time Factors , Treatment Outcome
13.
Rev. bras. oftalmol ; 74(5): 297-302, set.-out. 2015. tab, ilus
Article in Portuguese | LILACS | ID: lil-757447

ABSTRACT

Objetivo:Avaliar as alterações da biomecânica da córnea após laser de femtosegundo na cirurgia de catarata e comparar os parâmetros biomecânicos derivados do Corvis ST (Oculus Corvis ST, Scheimpflug Technology; Wetzlar, Germany) entre as técnicas do laser de femtossegundo e a facoemulsificação convencional após a cirurgia de catarata.Métodos:Estudo observacional, prospectivo envolvendo 151 olhos de 127 pacientes com diagnóstico de catarata nuclear. Setenta olhos de 65 pacientes foram submetidos à técnica do laser de femtossegundo (Alcon LenSx, Aliso Viejo,USA) e 76 olhos de 62 pacientes por meio da facoemulsificação convencional (Alcon Infinit, Fort Worth, USA). O sistema de tonometria de não contato integrado com a câmera ultrarrápida de Scheimpflug (Oculus Corvis ST, Scheimpflug Technology; Wetzlar, Germany) foi utilizado para avaliação da biomecânica da córnea antes e após a cirurgia de catarata pelas técnicas do laser de femtossegundo e a facoemulsificação convencional. Os parâmetros biomecânicos utilizados foram: deformidade de amplitude (DA), pressão intraocular, 1st A time, tempo de concavidade máxima, 2nd A time, 1st A Length, 2nd A Length, raio de curvatura de maior alcance, raio de curvatura normal, velocidade de entrada (Vin) e de saída (Vout). A densitometria do cristalino (scattering) através do PNS (Pentacam Nucleus Staging) foi realizado pela tomografia de córnea e segmento anterior (Pentacam® – Oculus, Wetzlar, Germany) em todos os pacientes para diagnóstico objetivo da opacidade do cristalino. Os critérios de exclusão foram: doença corneana, doenças da retina e/ou nervo óptico e cirurgia ocular prévia. O teste de Kolmogorov-Smirnov foi utilizado para avaliar a distribuição normal. O teste de Wilcoxon e o test-T foram utilizados para avaliação entre o pré-operatório e o primeiro dia de pós-operatório (D1) nos grupos do laser de femtossegundo (LFS) e do faco convencional (FC), respectivamente. O teste de Mann-Whitney foi realizado para avaliar as diferenças dos parâmetros biomecânicos da córnea derivados do Corvis ST entre os dois grupos (LFS; FC) após a cirurgia de catarata (D1). Foi considerado como estatisticamente significante p ≤ 0,05%.Resultados:A média de idade dos pacientes do grupo do LFS foi de 67,6 anos (± 9,9) e do grupo do FC foi de 68,4 anos (± 11,8).A média do PNS entre todos os pacientes (análise objetiva do cristalino) foi de 0,62 (± 0,67). No grupo do LFS, 9 dos 11 parâmetros foram estatisticamente significativos entre o Pré e D1; e no grupo do FC, 7 dos 11 parâmetros estudados foram estatisticamente significativos entre o Pré e D1. De todos os parâmetros biomecânicos derivados do Corvis ST estudados, somente o tempo de concavidade máxima da córnea (HC-time; p ≤ 0.0387) foi diferente entre os dois grupos (laser de femtossegundo x faco convencional) em D1.Conclusão:O laser de femtossegundo para cirurgia de catarata e a técnica de facoemulsificação convencional induziram alterações nas propriedades biomecânicas da córnea pelo Corvis ST no D1. Apenas 1 dos 11 parâmetros biomecânicos estudados foi diferente estatisticamente entre os grupos do LFS e FC.


Purpose:To evaluate the changes of corneal biomechanical after femtosecond laser – assisted cataract and to compare the parameters derived by Corvis ST between standard phacoemulsification and femtosecond laser – assisted in cataract surgeryMethods:This is a prospective study. 151 eyes of 127 patients were under went cataract surgery. 75 eyes of 65 patients were with femtosecond laser–assisted (FS)(Alcon Len Sx, Aliso Viejo,USA) and 76 eyes of 62 patients with standard phacoemulsification (SP) (Alcon Infinit, Fort Worth, USA). Lens scattering was evaluated using Scheimpflug Anterior Segment Tomography, using the new software PNS. The Scheimpflug images were taken with an ultra - high - speed camera during each measurement by the Corvis ST. The deformation amplitude (DA) and other parameters (e.g., pachyapex, intraocular pressure, 1st A time, highest concavity - time, 2nd A time, 1st A Length, 2nd A Length, curvature radius highest concavity, curvature radius normal, Vin, Vout) measured by the Corvis ST were studied in groups FLS and SP before an dafter cataract surgery. Exclusion criteria: corneal disease, retinal or optic nerves disease or previous ocular surgery. This is study analyzed was Kolmogorov-Smirnov for Normality. The Wilcoxon-test and t-test were utilized to evaluate the differences between pre and day 1in FS and SP, respectively. The Mann-Whitney test was used to compare the differences of parameters derived by Corvis ST - biomechanical properties between two groups (FS;SP). The p value less than 0.05 was considered statistically significant.Results:The mean age from patients of group FS was 67.6 y (± 9.9) and the group SP was 68.4 y (± 11.8). The mean PNS was 0.62 (±0.67). In group of FS, 9 of 11 parameters derived from Corvis ST were statisticall ysignificant (ss). In group of SP, 7 of 11 parameters derived from Corvis ST were ss. Only the HC - time was statistically significant between two groups (FS;SP) with p d” 0.0387.Conclusions:The use of the femtosecond laser – assisted system for cataract surgery and standard phacoemulsification induzed changes of biomechanical properties of the cornea by Corvis ST. Only 1 of 11 parameters studied was different statistically in two groups.


Subject(s)
Cataract Extraction , Cornea/physiopathology , Laser Therapy , Phacoemulsification , Biomechanical Phenomena , Observational Study , Prospective Studies
14.
Arq. bras. oftalmol ; 78(4): 236-240, July-Aug. 2015. tab
Article in English | LILACS | ID: lil-759255

ABSTRACT

ABSTRACTPurpose:To evaluate central corneal thickness (CCT) and peripheral corneal thickness (PCT) in patients with rheumatoid arthritis (RA) and to assess the relationships among the corneal parameters, dry eye disease, and clinical variables of RA.Methods:A total of 58 RA patients and 58 control subjects participated in this study. A detailed ophthalmological examination was performed on each subject. Dry eye evaluation was performed using Schirmer’s test, tear break-up time (TBUT), corneal fluorescein staining, and Ocular Surface Disease Index (OSDI). Corneal thickness at the apex point, the center of the pupil, the thinnest point, and PCT (3 mm from the apex to the superior, inferior, nasal, and temporal locations) were evaluated using Scheimpflug imaging (Pentacam®). Additionally, the relative peripheral index (RPI) was calculated by dividing the PCT by the CCT. The disease severity and quality of life were evaluated with DAS28 and HAQ, respectively. The laboratory evaluation comprised ESR and CRP.Results:The mean corneal thicknesses at the apex point, the center of the pupil, the thinnest point, and the superior, inferior, nasal, and temporal points were significantly thinner in RA patients than controls. Schirmer’s test scores and TBUT were significantly lower, and corneal staining and OSDI scores were significantly higher in RA patients. There were no significant correlations between the corneal parameters and the clinical variables of RA or dry eye tests.Conclusion:The CCT and PCT were thinner in RA patients compared to those in control subjects. However, there were no significant correlations between the corneal parameters and the clinical variables of RA or dry eye tests.


RESUMOObjetivo:Avaliar da espessura central da córnea (CCT) e espessura corneana periférica (PCT) em pacientes com artrite reumatoide (RA). O segundo objetivo foi avaliar as relações entre os parâmetros de córnea, doença do olho seco e variáveis clínicas da RA.Método:Um total de 58 pacientes com RA e 58 indivíduos do grupo controle participaram deste estudo. Exame oftalmológico detalhado foi realizado para cada indivíduo. Avaliação do olho seco foi realizada por meio do teste de Schirmer, tempo de ruptura do filme lacrimal (TBUT), coloração com fluoresceína da córnea e do índice de doença da superfície ocular (OSDI). Espessura da córnea no ápice, centro da pupila e ponto mais fino, assim como PCT (três milímetros do ápice para localização superior, inferior, nasal e temporal) foram avaliadas por meio de imagens Scheimpflug (Pentacam®). Além disso, o índice periférico relativo (RPI) foi calculado dividindo-se a PCT pela CCT. A gravidade da doença e qualidade de vida foram avaliados com DAS28 e HAQ respectivamente. A avaliação laboratorial foi composta por VHS e PCR.Resultados:As espessuras de córnea médias no ápice, centro da pupila, ponto mais fino, assim como nos pontos superior, inferior, nasal e temporal foram significativamente mais finas em pacientes com RA do que nos controles. Os resultados dos testes de Schirmer e TBUT foram significativamente menores e a coloração por fluoresceína e o OSDI foram significativamente maiores em pacientes com RA. Não houve correlações significativas entre os parâmetros da córnea e variáveis clínicas da RA ou testes de olho seco.Conclusões:A espessura corneana central e periférica foram mais finas em pacientes com RA em comparação com indivíduos controle. Não houve correlações significativas entre os parâmetros da córnea e variáveis clínicas da AR ou testes de olho seco.


Subject(s)
Female , Humans , Male , Middle Aged , Arthritis, Rheumatoid/pathology , Cornea/pathology , Corneal Topography/methods , Dry Eye Syndromes/diagnosis , Arthritis, Rheumatoid/physiopathology , Case-Control Studies , Cornea/physiopathology , Diagnostic Techniques, Ophthalmological , Dry Eye Syndromes/physiopathology
15.
Arq. bras. oftalmol ; 78(3): 150-153, May-Jun/2015. tab, graf
Article in English | LILACS | ID: lil-753025

ABSTRACT

ABSTRACT Purpose: The contrast sensitivity (CS) function in patients with primary Sjögren’s syndrome (pSS) may be impaired either frequently as a result of dry eye diseases or rarely as a result of optic neuropathy. In this study, we aimed to evaluate the CS function in pSS patients as well as to assess corneal aberrations and thickness of the peripapillary retinal nerve fiber layer (pRNFL). Methods: Fourteen eyes of 14 pSS patients (pSS group) and 14 eyes of 14 healthy participants (control group) were subjected to assessment of CS at the spatial frequencies of 1.5, 3.0, 6.0, 12, and 18 cycles/degree (cpd) using a functional visual acuity contrast test (FACT); measurement of corneal high-order aberrations (HOAs) in terms of coma-like, spherical-like, and total HOAs using Scheimpflug corneal topography; and measurement of the thickness of both the macular ganglion cell-inner plexiform layer (mGCIPL) and pRNFL in all quadrants using optical coherence tomography. None of the participants were under treatment with artificial tears. Results: The results of the CS test did not differ between the 2 groups at all spatial frequencies (p>0.05). In addition, there were no statistically significant differences between the 2 groups in terms of corneal HOAs (p>0.05) and thickness of mGCIPL (p>0.05). However, among all quadrants, only the inferior quadrant of pRNFL in pSS patients was statistically significantly thinner than that in the healthy participants (p=0.04). Conclusions: The CS function in pSS patients can be maintained with normal thickness of both pRNFL and mGCIPL and with lack of increased corneal HOAs, which may be present even in the absence of artificial tear usage. .


RESUMO Objetivo: A função de sensibilidade ao contraste em pacientes com síndrome de Sjögren primário (pSS) pode ser prejudicada, quer frequentemente como resultado de doenças do olho seco, ou mais raramente como um resultado de neuropatia óptica. Neste estudo, objetivamos avaliar a função de sensibilidade ao contraste de pacientes com pSS, além da avaliação das aberrações da córnea e a espessura da camada de fibras nervosas da retina (pRNFL). Métodos: Catorze olhos de 14 pacientes com pSS e 14 olhos de 14 participantes saudáveis foram submetidos, respectivamente, à avaliação do teste de sensibilidade aos contrastes (CS) nas frequências espaciais de 1,5, 3,0, 6,0, 12 e 18 ciclos/grau (cpd), utilizando teste de contraste acuidade visual funcional (FACT); a medida das aberrações de alta ordem da córnea (HOAs) em termos de coma, aberrações esféricas e aberrações totais, utilizando topografia corneana por Scheimpflug; e medida de espessura da camada de macular de células ganglionares plexiforme interna (mGCIPL) e a espessura de pRNFL em todos os quadrantes usando tomografia de coerência óptica. Nenhum dos participantes estava sob tratamento com lágrimas artificiais. Resultados: O teste CS em pacientes pSS não diferiu do que o teste CS em participantes saudáveis em todas as frequências espaciais (p>0,05). Não houve também nenhuma diferença estatisticamente significativa entre os dois grupos em termos de HOAs da córnea (p>0,05), e espessura de mGCIPL (p>0,05). No entanto, entre todos os quadrantes, apenas o quadrante inferior da pRNFL em pacientes pSS foi significativamente mais fino que o quadrante inferior da pRNFL em participantes saudáveis (p=0,04). Conclusões: A função de CS em doentes com pSS pode ser mantida em condições de ambas as espessuras normais de pRNFL e mGCIPL, assim como nas condições de falta de aumento HOAs da córnea, que pode ser mantida, mesmo na ausência do uso de lágrimas artificiais. .


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Contrast Sensitivity/physiology , Sjogren's Syndrome/physiopathology , Cornea/physiopathology , Corneal Wavefront Aberration/physiopathology , Nerve Fibers , Prospective Studies , Sjogren's Syndrome/diagnosis , Tomography, Optical Coherence/methods , Visual Acuity , Vision Tests/methods
16.
Rev. bras. oftalmol ; 73(1): 11-15, Jan-Feb/2014. tab, graf
Article in English | LILACS | ID: lil-712759

ABSTRACT

Objective: To compare refractive and vectorial outcomes of limbal relaxing incisions (LRI) versus toric intraocular lenses (IOL) in the treatment of preexisting corneal astigmatism at the time of phacoemulsification. Methods: This longitudinal observational case series assessed 62 eyes of 31 consecutive cataract patients with preoperative corneal astigmatism between 0.75 and 2.50 diopters in both eyes. Patients were randomly assorted in two groups: one assigned to receive AcrySof Toric™ IOL in both eyes, and another one assigned to have AcrySof Natural™ IOL associated with LRI, also in both eyes. All patients were re-evaluated, postoperatively, at 1, 3 and 6 months, when refractive astigmatism analysis was performed using vectorial methods proposed by Thibos. Variability of outcomes within each group and between groups were assessed and compared. Results: Manifest refractive cylinder, in diopters (D), as means ± standard deviation, in the LRI group for 1-month, 3-month and 6-month re-evalutions were respectively -0.66 ± 0.30; -0.70 ± 0.21 and -0.74 ± 0.26 when compared to -0.58 ± 0.24; -0.63 ± 0.20, and -0.62 ± 0.17 in the toric IOL group. (p value ≥ 0.06). Vectorial analysis evidenced greater astigmatism reduction in the toric IOL group in the 6th postoperative month, when postoperative mean astigmatic power vector was 0.31 D, when compared to 0.37 D in the LRI group (p value = 0.00). Conclusions: A trend of slightly better refractive outcomes favoring toric IOL group was seen, although such a trend was not statistically significant. Vectorial analysis, however, suggests that the use of toric IOL may constitute a more advantageous approach in the treatment of pre-existing corneal astigmatism, simultaneously with phacoemulsification. .


Objetivo: Comparar os resultados refracionais e de análise vetorial, das incisões relaxantes limbares (IRL) versus lentes intraoculares (LIO) tóricas no tratamento do astigmatismo corneano pré-existente por ocasião da facoemulsificação. Métodos: Estudo observacional longitudinal (série de casos) no qual foram avaliados 62 olhos de 31 pacientes consecutivos de catarata com astigmatismo corneano pré-operatório entre 0,75 e 2,50 dioptrias para ambos os olhos. Os pacientes foram aleatoriamente distribuídos entre 2 grupos: um submetido a implante de LIO AcrySof Toric™ em ambos os olhos e outo grupo no qual seriam implantas LIO AcrySof Natural™ complementada por IRL, também em ambos os olhos. Todos os pacientes foram reavaliados com 1, 3 e 6 meses de pós-operatório, sendo feitas análises do astigmatismo refracional pelo métodos vetorial proposto por Alpins, interessando a variação de resultados dentro de cada grupo e entre os grupos. Resultados: O cilindro refracional manifesto, em dioptrias, expresso como média ± desvio padrão, para o grupo IRL, nas avaliações de 1, 3 e 6 meses, foram respectivamente -0,66 ± 0,30; -0,70 ± 0,21 e -0,74 ± 0,26 em comparação aos -0,58 ± 0,24; -0,63 ± 0,20 and -0,62 ± 0,17 do grupo LIO tórica (valor de p ≥ 0,06). A análise vetorial evidenciou maior redução no astigmatismo no grupo LIO tórica no 6º mês pós-operatório, para o qual vetor de poder astigmático médio foi de 0,31 D, comparado ao de 0,37 D do grupo IRL (valor de p = 0,00). Conclusões: Tendência a melhores resultados refracionais favorecendo o grupo LIO tórica foi encontrada, entretanto, significância estatística não foi evidenciada ao longo do estudo. A análise vetorial, sugere ...


Subject(s)
Humans , Male , Female , Aged , Astigmatism/surgery , Limbus Corneae/surgery , Phacoemulsification/methods , Cornea/surgery , Lens Implantation, Intraocular , Lenses, Intraocular , Refraction, Ocular/physiology , Astigmatism/physiopathology , Cataract , Visual Acuity/physiology , Longitudinal Studies , Cornea/physiopathology , Corneal Topography , Diagnostic Techniques, Ophthalmological , Observational Study
17.
Korean Journal of Ophthalmology ; : 285-291, 2014.
Article in English | WPRIM | ID: wpr-156982

ABSTRACT

PURPOSE: To evaluate the changes of higher order aberrations (HOAs) before and after laser subepithelial keratomileusis (LASEK) and to analyze the influence of tear film instability on HOAs of the corneal surface after LASEK. METHODS: In this cross-sectional study, 31 patients who underwent LASEK were divided into dry eye (16 patients, 32 eyes) and non-dry eye groups (15 patients, 30 eyes). Uncorrected distance visual acuity, spherical equivalent refraction, ablation depth, tear film parameters and Ocular Surface Disease Index (OSDI) questionnaire scores were evaluated in both groups. Total HOA root mean square (RMS), third-order coma, third-order trefoil and fourth-order spherical aberration (SA) of the corneal surface immediately and at 10 seconds after blinking were measured before and after surgery. RESULTS: The total HOA RMS, coma, trefoil and SA significantly increased after LASEK compared with preoperative values in both groups. In the dry eye group, total HOA RMS, coma and trefoil significantly increased except for SA at 10 seconds after blinking compared with those measured immediately after blinking. In addition, the changes of total HOA RMS, coma and trefoil were negatively correlated with tear film break-up time (R = -0.420, -0.473 and -0.439, respectively), but positively correlated with OSDI score (R = 0.433, 0.499 and 0.532, respectively). In the non-dry eye group, there were no significant differences between HOAs measured at 10 seconds after blinking and those measured immediately after blinking. CONCLUSIONS: The HOAs including coma, trefoil and SA significantly increased after LASEK. The tear film instability in the dry eye can be associated with more deterioration of the optical quality after LASEK, due to more significant increase of total HOA RMS, coma and trefoil.


Subject(s)
Adult , Female , Humans , Male , Young Adult , Cornea/physiopathology , Corneal Wavefront Aberration/etiology , Cross-Sectional Studies , Dry Eye Syndromes/physiopathology , Keratectomy, Subepithelial, Laser-Assisted/adverse effects , Lasers, Excimer/therapeutic use , Surveys and Questionnaires , Tears/physiology , Visual Acuity/physiology
18.
Arq. bras. oftalmol ; 76(6): 339-340, nov.-dez. 2013. graf, tab
Article in English | LILACS | ID: lil-701282

ABSTRACT

PURPOSE: The aim of this study was to verify the presence of cyclotorsion in eyes that underwent laser refractive surgery. METHODS: This was a comparative observational study, which analyzed the medical records of 61 patients (104 eyes) who underwent laser refractive surgery and compared the axis of astigmatism of the sitting and the supine positions. Regarding the gender, 37.5% were male and 62.5% were female. The age ranged from 20 to 54 years old, with the median of 29 years. The lowest degree of astigmatism was -0.75 cylinder diopters (DC) and the highest was -6.50 DC, with a mean of -3.06 ± 1.16 DC. First, the axis of astigmatism of the seated patient was captured by the Schwind's ORK-CAM. In a second moment, inside the operating room, the axis of astigmatism of the patient in supine position was captured by the laser equipment's own camera (Schwind Amaris®), which was then compared with the previous measure. The incyclotorsion was defined by a minus sign (-) and the excyclotorsion, by a plus sign (+). RESULTS: The maximum excyclotorsion was +7.7 and the maximum incyclotorsion was -11.0 degrees. The mean torsion (excyclo or incyclo) was 2.74 (56.7%), with a standard deviation of 2.30 degrees. There was no statistically significant change (p=0.985) in the axis of astigmatism between patients sitting versus supine. CONCLUSION: There was clinically significant cyclotorsion in 36.5% of the eyes submitted to laser correction.


OBJETIVO: Verificar a presença de ciclotorção em olhos submetidos à cirurgia refrativa a laser. MÉTODOS: Realizou-se um estudo observacional comparativo, feito pela avaliação dos prontuários de 61 indivíduos (104 olhos) submetidos à cirurgia refrativa a laser, para comparar a orientação do astigmatismo ocular na posição sentada e em decúbito dorsal. Foram computados 37,5% de homens com idade variando de 20 a 54 anos, com mediana de 29 anos. O menor grau de astigmatismo avaliado foi de -0,75 e o maior de -6,50, com média de -3,06 ± 1,16 dioptrias cilíndricas (DC). A captação da orientação (eixo) do astigmatismo foi feita no primeiro momento (sentado) pelo aparelho ORK-CAM da empresa Schwind. Em um segundo momento (decúbito dorsal), na sala de cirurgia, o eixo foi captado pela câmera do próprio laser (Schwind Amaris®) para então comparar o eixo nos dois momentos. A inciclotorção foi identificada por um sinal negativo (-) e a exciclotorção por um sinal positivo (+). RESULTADOS: A exciclotorção máxima foi de +7,7 e a inciclotorção máxima de -11,0 graus. A média de torção (exciclo ou inciclo) foi de 2,74 (56,7%), com desvio padrão de 2,30 graus. Não houve variação estatisticamente significativa (p=0,985) no eixo do astigmatismo entre os indivíduos sentados versus decúbito dorsal. CONCLUSÃO: Houve ciclotorção clinicamente significativa em 36,5% dos olhos submetidos à cirurgia refrativa a laser.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Young Adult , Astigmatism/surgery , Cornea/surgery , Corneal Surgery, Laser/methods , Astigmatism/physiopathology , Cornea/physiopathology , Eye Movements , Medical Records , Reference Values , Severity of Illness Index , Statistics, Nonparametric , Supine Position , Torsion Abnormality , Treatment Outcome
19.
Rev. bras. oftalmol ; 72(6): 361-365, nov.-dez. 2013. graf, tab
Article in English | LILACS | ID: lil-704736

ABSTRACT

PURPOSE: To test whether corneal hysteresis (CH) and corneal resistance factor (CRF) can discriminate between keratoconus and normal eyes and to evaluate whether the averages of two consecutive measurements perform differently from the one with the best waveform score (WS) for diagnosing keratoconus. METHODS: ORA measurements for one eye per individual were selected randomly from 53 normal patients and from 27 patients with keratoconus. Two groups were considered the average (CH-Avg, CRF-Avg) and best waveform score (CH-WS, CRF-WS) groups. The Mann–Whitney U-test was used to evaluate whether the variables had similar distributions in the Normal and Keratoconus groups. Receiver operating characteristics (ROC) curves were calculated for each parameter to assess the efficacy for diagnosing keratoconus and the same obtained for each variable were compared pairwise using the Hanley–McNeil test. RESULTS: The CH-Avg, CRF-Avg, CH-WS and CRF-WS differed significantly between the normal and keratoconus groups (p<0.001). The areas under the ROC curve (AUROC) for CH-Avg, CRF-Avg, CH-WS, and CRF-WS were 0.824, 0.873, 0.891, and 0.931, respectively. CH-WS and CRF-WS had significantly better AUROCs than CH-Avg and CRF-Avg, respectively (p=0.001 and 0.002). CONCLUSION: The analysis of the biomechanical properties of the cornea through the ORA method has proved to be an important aid in the diagnosis of keratoconus, regardless of the method used. The best waveform score (WS) measurements were superior to the average of consecutive ORA measurements for diagnosing keratoconus.


OBJETIVO: Testar se a histerese corneana (CH) e o fator de resistência corneano (CRF) podem discriminar olhos com ceratocone e avaliar se a média de duas medidas consecutivas apresenta desempenho diferente da medida única com a melhor waveform score para diagnósticar o ceratocone. MÉTODOS: Foram realizadas medidas do ORA de um olho por indivíduo, selecionados aleatoriamente a partir de 53 pacientes normais e de 27 pacientes com ceratocone. Dois grupos foram considerados: a média (CH-médio, o CRF-médio) e melhor waveform score (CH-WS, CRF-WS). O teste de Mann-Whitney U-teste foi utilizado para avaliar se as variáveis apresentaram distribuições semelhantes entre os grupos. As curvas (ROC) foram calculadas para cada parâmetro para avaliar eficácia no diagnóstico e as obtidas para cada variável foram comparadas usando o teste de Hanley-McNeil. RESULTADOS: CH-médio, CRF-médio, CH-WS e CRF-WS diferiram significativamente entre os grupos (p<0,001). Já as áreas sob a curva ROC para CH-médio, CRF-médio, CH-WS, e CRF-WS foram 0,824, 0,873, 0,891, 0,931, respectivamente. CH-WS e CRF-WS obtiveram AUROCs significativamente melhores do que CH-médio e CRF-médio (p=0,001 e 0,002). CONCLUSÃO: A análise das propriedades biomecânicas da córnea através do ORA demonstrou ser um método auxiliar importante no diagnóstico de ceratocone, independente do método utilizado. As melhores medidas waveform score foram superiores à média das medições consecutivas para o diagnóstico de ceratocone.


Subject(s)
Humans , Male , Female , Child , Adolescent , Young Adult , Middle Aged , Keratoconus/diagnosis , Cornea/physiopathology , Diagnostic Techniques, Ophthalmological , Biomechanical Phenomena/physiology , ROC Curve
20.
Rev. bras. oftalmol ; 71(2): 115-118, mar.-abr. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-626586

ABSTRACT

Relato de caso de uma paciente, com córnea espessa, por distrofia de Fuchs em fase inicial, ainda com transparência corneana preservada (edema corneano subclínico), associado à pressão intraocular (PIO) normal por tonometria de aplanação de Goldman (TAG), que teve entretanto, o diagnóstico de glaucoma primário de ângulo aberto com base em alterações estruturais do nervo óptico. O estudo tomográfico demonstrou padrão de paquimetria espacial compatível com edema sub-clínico. O estudo biomecânico da córnea com o ORA (Ocular Response Analyzer, ® Reichert), associado à medida corrigida da PIO, possibilitou o entendimento da influência da córnea, que apesar de mais espessa, levava a uma TAG falsamente reduzida (hipoestimada). O estudo da PIO com sistema de tonografia digital de contorno (PASCAL) corroborou com os achados do ORA. Este exemplo ressalta a importância de novas tecnologias na avaliação de pacientes com suspeita de glaucoma, e destaca que a correção da TAG, com base em algoritmos lineares relacionados com a paquimetria central apenas, pode determinar sérios erros de interpretação clínica.


Case report of a patient, with a thick cornea, for Fuchs dystrophy in its early stages, yet with preserved corneal transparency (subclinical corneal edema), associated with normal intraocular pressure (IOP) by Goldman applanation tonometry (GAT), which was however, the diagnosis of primary open-angle glaucoma on the basis of structural changes of the optic nerve. The tomographic study showed a pattern of spatial pachymetry compatible with subclinical edema. The corneal biomechanical study with ORA (Ocular Response Analyzer, Reichert ®) associated with corrected IOP measurement, allowed the understanding of the corneal influence, which, although thicker, leading to a falsely low TAG (underestimated). The IOP study with tonography system digital (PASCAL) corroborated with the findings of ORA. This example highlights the importance of new technologies in patients' evaluation with suspected glaucoma, and highlights that the correction of TAG, based on linear algorithms related to central corneal thickness alone, can determine serious errors in clinical interpretation.


Subject(s)
Humans , Female , Middle Aged , Tonometry, Ocular/methods , Glaucoma, Open-Angle/diagnosis , Glaucoma, Open-Angle/physiopathology , Cornea/physiopathology , Corneal Pachymetry/methods , Optic Nerve/pathology , Biomechanical Phenomena , Fuchs' Endothelial Dystrophy/physiopathology , Glaucoma, Open-Angle/pathology , Cornea/pathology , Elasticity/physiology , Intraocular Pressure/physiology
SELECTION OF CITATIONS
SEARCH DETAIL